Air pressure adviser

Pressure drop
 
... inside the air supply - despite correct installation of compressed air lines, compressor and refrigerant dryer
 
Reason:
 
  • Too many heavy users, operated sporadically
    Cause of problem:
    Coating or sanding processes etc. are being conducted simultaneously
    Remedies:
    - Install additional compressor
    - Organize work in a way that excessive charges are eliminated or reduced
    - Install additional pressure compensation container for reducing the air volume capacity
  • Installation of an absorption dryer
    Cause of problem:
    The auto-regeneration of the absorbtion dryer (cold regeneration) causes approx. 10 % of the compressed air volume to be blown into the atmosphere, even if no compressed air is being consumed
    Remedies:
    - Uninstall absorption dryer
    - Install absorption dryer with warm regeneration
    - Instead of an absorption dryer, install a cold dryer which consumes no air
    - Install new, larger compressor
  • Installation of an absorption dryer with warm regeneration
    Cause of problem:
    The absorption dryer with warm regeneration causes 2 - 3 % of the compressed air volume fed to be blown into the atmosphere
    Remedies:
    - Uninstall absorption dryer; increase compressor unit; install new compressor.
  • Installation of a diaphragm dryer
    Cause of problem:
    The installation of a diaphragm dryer (HighTec) causes approx. 20 - 30 % of the air volume to be blown into the atmosphere, even when no compressed air is being consumed
    Remedies:
    - Uninstall diaphragm dryer
    - Enlarge compressor and compressed air system correspondingly
    - Install corresponding filtration
  • Air line diameter reductions caused by dirt
    Cause of problem:
    Too much dirt in the compressed air line may affect the function of the automatic condensate discharge and other valves
    Remedies:
    - Sufficiently clean and dry compressed air lines
    - Replace valves and pipes
 

   
 
© 2002-2007 - Copyright SATA GmbH & Co. KG, Kornwestheim, Germany - Dan-Am Company, Spring Valley MN USA
All photos, logos and text of SATA products contained on this web site are the property of SATA GmbH & Co. KG.
DanAm is a fully independent company that is acting as the authorized importer and distributor for SATA branded products - and Dan-Am is responsible for the content shown on www.sata.com/USA .
DanAm has the sole responsibility for the contents of the website.
Other products referrenced within this website are property of Dan-Am Co.
Except for customer information, any use of text, logos and photos by individuals or companies from these pages without written consent is strictly prohibited. Technical alterations reserved. SATA, SATAjet, the SATA Logo and/or other SATA products referenced herein are either registered trademarks or trademarks of SATA GmbH & Co. KG in the U.S. and/or other countries. The names of companies and products mentioned herein may be the trademarks of their respective owners.
 ...more...